127
1-3-2 Remote Console
Use the mode setting selector of the dedicated CQM1-TU001 Remote Console
for the CQM1-SEN01 to set sensor modules mounted to the CQM1-SEN01 to
operation monitor mode or teaching mode.
1-3-3 Sensor Modules
The following dedicated sensor modules can be mounted to the CQM1-SEN01.
Name
Model
Optical Fiber Photoelectric Module
E3X-MA11
Photoelectric Module
E3C-MA11
Proximity Sensor Module
E2C-MA11
Dummy Module
E39-M11
Note Mount the E39-M11 Dummy Module to any unused slot of the CQM1-SEN01 for
dust prevention.
1-3-4 Applicable Sensors
The following sensors can be used with the E3X-MA11 Optical Fiber Photoelec-
tric Module.
Sensing method
Model
Thru-beam
E32-T11L, E32-TC200, and E32-T11
Side view thru-beam
E32-T14L
Heat-resistive thru-beam
E32-T51
Screen thru-beam
E32-T16
Reflective
E32-D11L, E32-DC200, and E32-D11
Side view reflective
E32-D14L
Heat-resistive reflective
E32-D51
Retroreflective
E32-R21
Note The E3X-MA11 can be used with a variety of sensors in addition to those listed
above. The E3X-MA11, however, cannot be used with the E32-DC9G,
E32-DC9G4, E32-D61, or E32-D73.
The following sensors can be used with the E3C-MA11 Photoelectric Module.
Sensing method
Model
Thru-beam
E3C-S10, E3C-1, and E3C-2
Diffuse reflective
E3C-DS5W, E3C-DS10
Convergent reflective
E3C-LS3R
Mark detection reflective
E3C-VS1G, E3C-VS3R, E3C-VM35R,
and E3C-VS7R
The following sensors can be used with the E2C-MA11 Proximity Sensor Module.
•
E2C-CR5B
•
E2C-CR8A
•
E2C-CR8B
•
E2C-X1A
•
E2C-C1A
•
E2C-X1R5A
Connecting Devices
Section 1-3
Summary of Contents for CQM1H - 08-2005
Page 1: ...Cat No W238 E1 8 Dedicated I O Units CQM1H CQM1 series OPERATION MANUAL SYSMAC ...
Page 2: ......
Page 3: ...CQM1H CQM1Series Dedicated I O Units Operation Manual Revised August 2000 ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 21: ...1 PART I B7A Interface Unit CQM1 B7A02 CQM1 B7A03 CQM1 B7A12 CQM1 B7A13 CQM1 B7A21 ...
Page 22: ......
Page 42: ......
Page 45: ...25 PART II G730 Interface Unit CQM1 G7M21 CQM1 G7N01 CQM1 G7N11 ...
Page 46: ......
Page 62: ......
Page 72: ......
Page 74: ...Appendix A Specifications 54 Dimensions Common for Master and Expansion Master Unit mm ...
Page 78: ......
Page 79: ...59 PART III I O Link Unit CQM1 LK501 ...
Page 80: ......
Page 88: ......
Page 92: ......
Page 93: ...73 PART IV Analog Input Unit and Analog Power Supply Units CQM1 AD041 CQM1 IPS01 CQM1 IPS02 ...
Page 94: ......
Page 118: ......
Page 120: ......
Page 121: ...101 PART V Analog Output Unit and Analog Power Supply Units CQM1 DA021 CQM1 IPS01 CQM1 IPS02 ...
Page 122: ......
Page 126: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 156: ......
Page 172: ......
Page 186: ......
Page 187: ...167 PART VII Linear Sensor Interface Units CQM1 LSE01 CQM1 LSE02 ...
Page 188: ......
Page 192: ......
Page 204: ......
Page 218: ......
Page 238: ......
Page 242: ......
Page 246: ......
Page 248: ......
Page 250: ......