![background image](http://html1.mh-extra.com/html/omron/c200hw-srm21-v1-cs1w-srm21/c200hw-srm21-v1-cs1w-srm21_operation-manual_742333226.webp)
205
Connector Terminals
Section 5-2
Note
1.
The size of the sensor cable conductor is calculated as below.
Conductor description of sensor cable:
φ
Outside diameter of cable (number of wires/wire diameter)
conductor size (mm
2
)
= (wire diameter/2)
2
×
π
×
number of wires
Example: E3S-A Sensor
φ
4 (18/0.12)
→
Conductor size (mm
2
)
= (0.12/2)
2
×
3.14
×
18 = 0.20
Since the conductor size works out to be 0.2 mm
2
, use XS8A-0442 Con-
nector.
2.
The XS8A-0441 and XS8A
-
0442 Connectors are not provided with the
Unit. The Connectors must be ordered separately.
Models with MIL Connectors (SRT2-VID16ML-1)
The MIL Connector can be connected to external devices using either of the
following methods.
1,2,3...
1.
Using an XG4A-2030-T MIL Connector (sold separately) to Assemble Your
Own Cable
For details, refer to
MIL Connector Wiring and Assembly
Yes
No
Yes
No
Is the input power supply
voltage 20.4 to 26.4 V DC?
Incompatible
Do input specifications agree?
What is the size of the
conductors in the cable?
Compatible
Use an XS8A-0441 Connector to
connect the sensor.
0.3 to 0.5 mm
2
0.14 to 0.2 mm
2
Compatible
Use an XS8A-0442 Connector to
connect the sensor.
Incompatible
Incompatible
Other
Insert with protrusion
facing right.