349
Sensor Amplifier Terminals
Section 5-11
4
5
6
Set the mode selector to RUN to complete the sensitivity set-
ting.
The teaching indicator (green) is OFF.
7
Select the logical output required with the operation mode
selector.
Procedure
Operation
E3X-NT
E3X-NM
Light is interrupted.
Locate a sensing object in the sensing area and press the
teaching button once. In the case of the E3X-NM, select a
channel with the channel selector and press the teaching
button, at which time the stability indicator for the selected
channel will flash.
The teaching indicator (red) is lit.
The built-in buzzer beeps once.
Through-beam Model
Reflective Model
Reflective Model
Mark
Base
TEACH
TEACH
Light is received.
Move the object and press the teaching button.
If teaching is OK: The teaching indicator (red) turns green.
The built-in buzzer beeps once.
If teaching is NG: The teaching indicator (red) starts flashing.
The operation indicator also starts flashing.
(E3X-NM)
The built-in buzzer beeps 3 times.
Change the position of the object and the sensing distance
that have been set and repeat from the beginning.
Through-beam Model
Reflective Model
Reflective Model
Mark
Base
TEACH
TEACH
TEACH
RUN
TEACH
TIMER
SET
RUN
L
D
ON
ON
1
2
3
4
L ON
D ON
CH