267
Remote I/O Modules
Section 5-3
2.
NC Terminal:
• The NC terminal is used internally. Therefore, do not connect anything
to the NC terminal.
Inner-layer Pattern for Noise Protection
When adding a noise protection circuit to the input or output section, create
inner-layer patterns as follows:
• There must be at least 2.54 mm between the adjacent inner-layer pat-
terns of the external and internal circuits.
• The inner-layer pattern of the external circuit must be kept at least 10 mm
from each terminal of the SRT
@
-ID16P or SRT
@
-OD16P,
No parts must be mounted on the soldered surfaces around the SRT
@
-ID16P
or SRT
@
-OD16P.