5-44
5.51 Lamp
1. Remove the book cover.
2. Remove the upper right cover.
3. Remove the upper rear cover.
4. Remove the upper front cover.
5. Remove the book scanner glass.
6. Remove the mirror carriage A.
7. Remove the cable link A mounting screw, and then remove the cable link A.
8. Remove the lamp connector from the cable link.
9. Release the two locking tabs, and then remove the lamp holder.
10. Remove the lamp.
Note: Perform a background level setting whenever a lamp is exchanged.