![Oki OKIOFFICE 120 Maintenance Manual Download Page 75](http://html1.mh-extra.com/html/oki/okioffice-120/okioffice-120_maintenance-manual_3849461075.webp)
3-34
Unique Switch B:6 - Transmission
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
1
F-code sub-frame off
0: Send
1: Not send
Do not send the sub-address and password of F-
code box when a point of sending DCS signal after
EOM signal.
3
0
Send F-code box’s TTI
0: No
1: Yes
Transmit the sub-address and box name of F-code
box with F-code polling document.
2
1
Factory use only
1
0
Retrieve document
0: No
1: Yes
Retrieve the document received in F-code
SecureMail box by polling transmission.
0
1
Ignore F-code bit
0: No
1: Yes
Neglect SEP bit of DTC signal or SUB bit of DCS
signal at F-code polled transmission.
Unique Switch B:7
∼∼
B:9 --- Factory use only
Unique Switch C:0 - Reception
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
1
MMR storage
0: No
1: Yes
Determines how documents are stored in memory
for transmission.
4
1
Transmit CED signal when
manual/remote receive
0: No
1: Yes
Determines if sending CED signal at on-hook
transfer.
3
1
Factory use only
2
0
Factory use only
1
1
Print a page completed to
receive during receiving into
memory
0: No
1: Yes
Determines if printing a page which completed to
receive the data during receiving it into fax’s
memory.
0
1
Avoid time out in ECM
reception
0: No
1: Yes
Disables 60 seconds RNR time out in ECM mode.
Summary of Contents for OKIOFFICE 120
Page 7: ...vi ...
Page 17: ...1 10 1 7 Dimensions Dimension in mm ...
Page 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Page 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Page 25: ...2 2 ...
Page 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...