![Oki OKIOFFICE 120 Maintenance Manual Download Page 63](http://html1.mh-extra.com/html/oki/okioffice-120/okioffice-120_maintenance-manual_3849461063.webp)
3-22
Memory Switch D:0 - Reception
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Number of HDLC end flags
Defines the number of HDLC end flags.
Switch 7 6 5 4
0 0 0 0 1
6
0
0 0 0 1 2
0 0 1 0 3 Default
0 0 1 1 4
0 1 0 0 5
0 1 0 1 6
5
1
0 1 1 0 7
0 1 1 1 8
1 0 0 0 9
1 0 0 1 10
1 0 1 0 11
4
0
1 0 1 1 12
1 1 0 0 13
1 1 0 1 14
1 1 1 0 15
1 1 1 1 16
3
0
Factory use only
2
1
Group delay compensation
0: No
1: Yes
As if two exchangers are selected to communicate
each other, compensate the group delay.
1
0
Digital cable equalizer
0: Free
1: Hold
When set to “1”, become efficient for the line short
break, but become weak for the line noise. It’s
available only for communication at 14,400 or
12,000 bit/s.
0
1
Carrier detection level
0: -43/48 dB
1: -47/52 dB
Setting this switch to “1” increases the sensitivity.
Memory Switch D:1 - Reception
Switch
Initial
Setting
Adjust
Usage/Comments
7
1
EYE-Q check level at
0 0 1 1
6
0
7200 bps
Strict-- - - - - - - - - - - -Lenient
0 1 0 1
5
1
EYE-Q check level at
0 0 1 1
4
0
9600 bps
Strict - - - - - - - - - - - -Lenient
0 1 0 1
3
1
EYE-Q check level at
0 0 1 1
2
0
12000 bps
Strict - - - - - - - - - - - -Lenient
0 1 0 1
1
1
EYE-Q check level at
0 0 1 1
0
0
14400 bps
Strict - - - - - - - - - - - -Lenient
0 1 0 1
Summary of Contents for OKIOFFICE 120
Page 7: ...vi ...
Page 17: ...1 10 1 7 Dimensions Dimension in mm ...
Page 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Page 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Page 25: ...2 2 ...
Page 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...