3-16
Memory Switch A:0 - Dialer
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
DIS detect time after dialing
0: 55 sec
1: 70 sec
Sets the time DIS signal is detected after dialing a
number.
2
1
CED detection
0: No
1: Yes
Can be use to ignore CED detection if noise on the
telephone line is mistaken as a 2100 Hz CED
signal.
1
1
Dial tone detection
0: Do not dial
1: Dial
Determines if the unit proceeds with dialing or
indicates an error if no dial tone is detected within
five seconds of going off-hook.
0
0
Phone line type
0: PSTN
1: PBX
When set to PSTN, the unit checks for dial tone
and acts according to the setting of memory switch
A:0, bit 1. When set to PBX, the unit always dials a
given number of seconds after going off-hook.
Memory switch A:1 sets the number of seconds.
Memory Switch A:1 - Dialer
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
PBX mode dial pause
Sets the number of seconds the unit waits before
dialing when memory switch A:2, bit 0 is set to PBX
mode.
Switch 3 2 1 0 Pause time
0 0 0 0 0 sec
2
0
0 0 0 1 1 sec
0 0 1 0 2 sec
0 0 1 1 3 sec Default
0 1 0 0 4 sec
0 1 0 1 5 sec
1
1
0 1 1 0 6 sec
0 1 1 1 7 sec
1 0 0 0 8 sec
1 0 0 1 9 sec
1 0 1 0 10 sec
0
1
1 0 1 1 11 sec
1 1 0 0 12 sec
1 1 0 1 13 sec
1 1 1 0 14 sec
1 1 1 1 15 sec
Memory Switch A:2
∼∼
A:4 --- Factory use only
Summary of Contents for OKIOFFICE 120
Page 7: ...vi ...
Page 17: ...1 10 1 7 Dimensions Dimension in mm ...
Page 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Page 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Page 25: ...2 2 ...
Page 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...