![Oki OKIOFFICE 120 Maintenance Manual Download Page 85](http://html1.mh-extra.com/html/oki/okioffice-120/okioffice-120_maintenance-manual_3849461085.webp)
3-44
Unique Switch F:2 - Printer
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Printer auto shut off time
Time until the power supply turns the fusing unit off
after printing has completed.
6
0
Switch 7 6 5 4 3 2 1 0 Time
0 0 0 0 0 0 0 0 0 min
5
0
0 0 0 0 0 0 0 1 1 min
0 0 0 0 0 0 1 0 2 min
4
0
0 0 0 0 0 1 0 1 5 min Default
3
0
2
1
1
0
1 1 1 1 1 1 0 0 252 min
1 1 1 1 1 1 0 1 253 min
0
1
1 1 1 1 1 1 1 0 254 min
1 1 1 1 1 1 1 1 255 min
Unique Switch F:3 - Printer
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Switch 2 1 0
0 0 0
Lightest
0 0 1
Light
1
0
Printing density
0 1 0
Not as light
0 1 1 Normal
Default
1 0 0
Dark
0
0
1 0 1
Darkest
Over 1 1 0
Normal
Note: This is a 6 position switch.
Unique Switch F:4 --- Factory use only
Summary of Contents for OKIOFFICE 120
Page 7: ...vi ...
Page 17: ...1 10 1 7 Dimensions Dimension in mm ...
Page 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Page 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Page 25: ...2 2 ...
Page 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...