6-6
EZ I/O
6000 Series user’s manual
≡
Model 6050
Sixteen of the 24 lines can be individually programmed as inputs or
outputs. These are divided into two groups of 8 lines with 10K resistors
that can be pulled to ground or +5V. As output lines, they can sink and
source 15 mA.
The remaining 8 lines are dedicated high current outputs, using a
ULN2804 high current Darlington array. The outputs are open collec-
tors and are capable of driving loads up to 100 mA at 50V.
6050 — Pulling the I/O lines high or low
Jumper block W2 pulls the I/O lines at ports A and C high or low. The
default pulls all of the I/O lines high.
Note
For the location of W2, refer to the component diagram in the 6050
technical data appendix.
Table 6-6
6050 pull-up/pull-down EZ I/O
Configuration
Description
W2[2–4]*
All lines in Port A are pulled to +5V through 10K Ohm
W2[4–6]
All lines in Port A are pulled to Gnd through 10K Ohm
W2[1–3]*
All lines in Port C are pulled to +5V through 10K Ohm
W2[3–5]
All lines in Port C are pulled to
Gnd
through 10K Ohm
* = default, pins jumpered
Note
Port B of model 6050 is dedicated as a high current output port and is
not affected by the position of W2.
6050 — Organization of ports
The EZ I/O digital port has a total of 24 I/O lines connected to J1. The
lines are configured into three groups: port A, port B, and port C, each
consisting of 8 bits. Any of the lines at ports A or C can be configured
individually as inputs or outputs. Port B is dedicated as the high cur-
rent port and can only be configured as outputs. Immediately after a
reset, each I/O line on ports A and C becomes an input, and port B
drivers are off.
Summary of Contents for 6000 Series
Page 7: ...Notice to user PC 500 user s manual ...
Page 9: ...About this manual 6000 Series user s manual ...
Page 37: ...2 20 Quick start 6000 Series user s manual ...
Page 65: ...5 16 Serial ports 6000 Series user s manual ...
Page 87: ...6 22 EZ I O 6000 Series user s manual ...
Page 103: ...8 8 Analog I O 6000 Series user s manual ...
Page 119: ...14 2 PC 104 expansion 6000 Series user s manual ...
Page 133: ...16 4 Watchdog timer reset and remote reset 6000 Series user s manual ...
Page 139: ...17 6 Serial EEPROM 6000 Series user s manual ...
Page 157: ...21 2 Software utilities 6000 Series user s manual ...
Page 161: ...22 4 Troubleshooting 6000 Series user s manual ...
Page 177: ...A 16 6010 technical data 6000 Series user s manual ...
Page 215: ...D 16 6040 technical data 6000 Series user s manual ...
Page 229: ...F 2 Miscellaneous 6000 Series user s manual ...