5-15
6000 Series user’s manual
Serial ports
Remote replies: (Dear 00: 02 internal state = 47.)
>00W024784.
; >
;message start character
; 00
;intended listener is ID 00 (host)
; W
;command code W (reply to internal state query)
; 02
;02 = my ID
; 47 ;47 = my internal state
; 84;checksum = uchar (‘0’+’0’+’W’+’0’+’2’+’4’+’7’) = 0x84
; .;message end character
The application program interprets the message and then responds
accordingly. In this case, state 47 would have been defined in the host
application as a specific response from a Remote with a user-defined
meaning.
≡
6030
COM3/COM4
The 6030 PC Microcontroller has two additional serial ports. COM3
uses IRQ12 at I/O address 3E8H. COM4 uses IRQ11 at I/O address
2E8H. Both COM ports have 4 RS-232 signals available: RxD, TxD,
RTS, and CTS. DTR is pulled high. Refer to the 6030 technical data
appendix for pinout information.
Summary of Contents for 6000 Series
Page 7: ...Notice to user PC 500 user s manual ...
Page 9: ...About this manual 6000 Series user s manual ...
Page 37: ...2 20 Quick start 6000 Series user s manual ...
Page 65: ...5 16 Serial ports 6000 Series user s manual ...
Page 87: ...6 22 EZ I O 6000 Series user s manual ...
Page 103: ...8 8 Analog I O 6000 Series user s manual ...
Page 119: ...14 2 PC 104 expansion 6000 Series user s manual ...
Page 133: ...16 4 Watchdog timer reset and remote reset 6000 Series user s manual ...
Page 139: ...17 6 Serial EEPROM 6000 Series user s manual ...
Page 157: ...21 2 Software utilities 6000 Series user s manual ...
Page 161: ...22 4 Troubleshooting 6000 Series user s manual ...
Page 177: ...A 16 6010 technical data 6000 Series user s manual ...
Page 215: ...D 16 6040 technical data 6000 Series user s manual ...
Page 229: ...F 2 Miscellaneous 6000 Series user s manual ...