8-1
6000 Series user’s manual
Analog I/O
Chapter 8:
Analog I/O
Note
Analog I/O is only available on the 6040 PC Microcontroller.
≡
Description
The 6040 has eight input channels and two analog output channels, all
with 12 bits of resolution. It can read and write data at 100,000
samples per second.
The range of each input channel is independently software selectable for
±10V, ±5V, 0 to 10V, or 0 to 5V. An adjustment potentiometer is pro-
vided to adjust the selected input voltage range by +5%. The input
multiplexer is fault protected to ±16.5V. The input resistance is 10M
Ω
.
The output ranges are individually jumperable for ±5V, 0 to 10V, or 0 to
5V. Both the analog input and analog output lines are located at J7.
WARNING!
The analog output channels come up in an undefined state
until they are configured in your software. Critical systems
should be disabled until the analog output channels are
initialized to a known state.
Summary of Contents for 6000 Series
Page 7: ...Notice to user PC 500 user s manual ...
Page 9: ...About this manual 6000 Series user s manual ...
Page 37: ...2 20 Quick start 6000 Series user s manual ...
Page 65: ...5 16 Serial ports 6000 Series user s manual ...
Page 87: ...6 22 EZ I O 6000 Series user s manual ...
Page 103: ...8 8 Analog I O 6000 Series user s manual ...
Page 119: ...14 2 PC 104 expansion 6000 Series user s manual ...
Page 133: ...16 4 Watchdog timer reset and remote reset 6000 Series user s manual ...
Page 139: ...17 6 Serial EEPROM 6000 Series user s manual ...
Page 157: ...21 2 Software utilities 6000 Series user s manual ...
Page 161: ...22 4 Troubleshooting 6000 Series user s manual ...
Page 177: ...A 16 6010 technical data 6000 Series user s manual ...
Page 215: ...D 16 6040 technical data 6000 Series user s manual ...
Page 229: ...F 2 Miscellaneous 6000 Series user s manual ...