A-3
6000 Series user’s manual
6010 technical data
Bus mastering
Bus mastering is not supported
Power requirements
5V ±0.25V @ 1.0 Amp. maximum
Full 40MHz operation:
480mA typical
Suspend:
167mA typical
Environmental specifications
–40° to 85° C when operating at 25 MHz
0° to 60° C when operating at 40 MHz
Note
Use of a heat sink is required to achieve the high end of the
temperature range.
–55° to 90° C, nonoperating
RH 5% to 95%, noncondensing
Size
4.5 in. x 4.9 in.
Mating connectors
J1 PC/104 interface, PC/104 8/16-bit receptacle:
For 8-bit:
Samtec #ESQ-132-14-G-D
For 16-bit:
Samtec #ESQ-120-14-G-D
J2 AUX I/O port, 34-pin shrouded header:
Receptacle:
AMP #746288-8
Strain relief: AMP #499252-6
J3 and J4 serial ports, 10-pin shrouded header:
Receptacle:
AMP #746288-1
Strain relief: AMP #499252-5
J6 battery, 4-pin in-line connector:
Housing:
DuPont BERG #746288-1
Crimp to wire pins: DuPont BERG #499252-5
J7 IDE hard drive port, 44-position 2 mm x 2 header:
Receptacle:
AMP #111626-0
J8 floppy port, 34-pin shrouded header:
Receptacle:
AMP #746288-8
Strain relief: AMP #499252-6
Summary of Contents for 6000 Series
Page 7: ...Notice to user PC 500 user s manual ...
Page 9: ...About this manual 6000 Series user s manual ...
Page 37: ...2 20 Quick start 6000 Series user s manual ...
Page 65: ...5 16 Serial ports 6000 Series user s manual ...
Page 87: ...6 22 EZ I O 6000 Series user s manual ...
Page 103: ...8 8 Analog I O 6000 Series user s manual ...
Page 119: ...14 2 PC 104 expansion 6000 Series user s manual ...
Page 133: ...16 4 Watchdog timer reset and remote reset 6000 Series user s manual ...
Page 139: ...17 6 Serial EEPROM 6000 Series user s manual ...
Page 157: ...21 2 Software utilities 6000 Series user s manual ...
Page 161: ...22 4 Troubleshooting 6000 Series user s manual ...
Page 177: ...A 16 6010 technical data 6000 Series user s manual ...
Page 215: ...D 16 6040 technical data 6000 Series user s manual ...
Page 229: ...F 2 Miscellaneous 6000 Series user s manual ...