ERR005197
Chip Errata for the i.MX 6Dual/6Quad and i.MX 6DualPlus/6QuadPlus, Rev. 6.1, 06/2016
136
NXP Semiconductors
Description:
The data sent through Null or Blanking data packets do not activate ‘dvalid’ signal. CSI-2 Host
controller implementation currently activates ‘dvalid’ for payload of any kind of long packet. The
IP should match what is described in the databook and ‘dvalid’ should not be activated by Null and
Blanking data.
Projected Impact:
None.
Workarounds:
The ‘dvalid’ signal can be filtered by configuring the following IPU data type registers:
• IPU_CSI0_DI__CSI0_MIPI_DI1
• IPU_CSI0_DI__CSI0_MIPI_DI2
• IPU_CSI0_DI__CSI0_MIPI_DI3
Proposed Solution:
No fix scheduled
Linux BSP Status:
Workaround possible but not implemented in the BSP, impacting functionality as described above.
ERR005197
MIPI: Null and Blanking data packets activate ‘dvalid’ signal