ERR005195
Chip Errata for the i.MX 6Dual/6Quad and i.MX 6DualPlus/6QuadPlus, Rev. 6.1, 06/2016
134
NXP Semiconductors
Description:
When the HBP programmed timing is shorter than the time required to transmit the smallest
blanking packet (6 bytes long packet), the controller incorrectly sends a blanking packet. This
incorrect behavior models the HBP for a longer period than expected while the core should decide
not to send any blanking packet. The transmission of blanking packet under these conditions can
only be observed in Video Synchronous Mode with pulses.
Projected Impact:
Incorrect video stream in some conditions.
Workarounds:
HSA and HBP should be programmed with values higher than 10 lane byte cycles. The 10 lane
byte clock corresponds to the transmission of a Horizontal Sync Start packet (4 bytes) followed by
the smallest blanking packet (6 bytes).
Proposed Solution:
No fix scheduled
Linux BSP Status:
Software workaround not implemented in Linux BSP. Functionality or mode of operation in which
the erratum may manifest itself is not used.
ERR005195
MIPI: Incorrect blanking packet may be sent by the MIPI DSI interface