September 2007
Configuring Non-Facility Associated Signaling
Installation Guide
87
4
Now we will align the Trunk Spans from the Switch side to the Ai Logix
card side. The NFAS configuration requires some very specific alignment
with regard to the D-channel configuration and Ai Logix Card IDs. We
must obey the following rules:
a.
The D-channel and Backup of the same Switch Trunk Group must be
connected to the same DP6409 card.
b.
The D-channel Trunk Span must be connected to the Top (or left-
hand) port on the DP6409. The Backup must be connected to the
Bottom (or right-hand) port on the DP6409.
c.
The D-channel and Backup must be connected to the card with the
lowest Ai Logix Card ID for that Switch Trunk Group.
5
Locate Ai Logix Card ID 0 and align it with the D-channel and Backup of
your first Switch Trunk Group. Follow up the Ai Logix Card IDs along with
the remaining Trunk Spans in the Switch Trunk Group so that the card
IDs align with the Switch Trunk Span Indexes.
Ai Logix Card ID
Ai Logix Serial #
0
0582
1
0468
2
3660
3
3656
4
3726
5
3700
Summary of Contents for TDM Recorder
Page 2: ......
Page 12: ...Getting Started Standard 3 0 12 Nortel TDM Recorder...
Page 38: ...Recorder Hardware Installation Standard 3 0 38 Nortel TDM Recorder...
Page 64: ...Recorder Software Installation Standard 3 0 64 Nortel TDM Recorder...
Page 78: ...Uninstalling and Upgrading Recorder Standard 3 0 78 Nortel TDM Recorder...
Page 94: ...Configuring Non Facility Associated Signaling Standard 3 0 94 Nortel TDM Recorder...
Page 126: ...Voice Card Configurations Standard 3 0 126 Nortel TDM Recorder...
Page 127: ......