This option is used as a simple parameterisation, display and control tool for the SK 200E frequency
inverter.
Features
4-digit, 7-segment LED display
Complete parameterisation of the frequency inverter.
Direct control of a frequency inverter
Displays the active parameter set during
parameterisation and operation and the operating
value set in P001.
After the SimpleBox has been connected and the mains switched on, horizontal lines appear in the 4-digit 7-
segment display. This display signals the operational readiness of the frequency inverter.
If a creep frequency value is pre-set in parameter P113, or a minimum frequency or setpoint value is pre-set
in P104, the display flashes with this initial value.
If the frequency inverter is enabled, the display changes automatically to the operating value selected in
parameter >Selection Display value< P001 (factory setting = current frequency).
The actual parameter set in use is shown by the 2 LEDs next to the display on the left in binary code.
NOTE
The digital frequency setpoint is factory set to 0Hz. To check whether the motor is working, a
frequency setpoint must be entered with the
/
key or a jog frequency via the
respective parameter >Jog frequency< (P113).
Settings should only be implemented by qualified personnel, strictly in accordance with the
warning and safety information.
ATTENTION:
The motor may start immediately after pressing the START key
!