Parameter
Setting value / Description / Note
Device
Supervisor
Paramter-
satz
P740
... - 01
...
... - 13
Process data Bus In
S
0000 ... FFFF (hex)
This parameter provides information about the actual control word (STW) and the setpoints
(SW1-3) that are transferred via the bus systems.
For values to be displayed, a bus system must be selected in P509.
[ - 01 ] =
Control word
Control word, source from P509.
[-02]
= Setpoint 1 (P546)
[-03]
= Setpoint 2 (P547)
[-04
]= Setpoint 3 (P548)
Setpoint data from main setpoint P510 - 01.
[ - 05 ] =
Bus I/O In Bits (P480)
The displayed value depicts all Bus In Bit sources
linked with
or
.
[ - 06 ] =
Parameter data In 1
[ - 07 ] =
Parameter data In 2
[ - 08 ] =
Parameter data In 3
[ - 09 ] =
Parameter data In 4
[- 10] =
Parameter data In 5
Data during parameter transfer: Order label (AK),
Parameter number (PNU),
Index (IND), Parameter value (PWE 1/2)
[ - 11 ] =
Setpoint 1
[ - 12 ] =
Setpoint 2
[ - 13 ] =
Setpoint 3
Setpoint data from the master function value
(broadcast), if P509/510 = 4 (P502/P503)
P741
... - 01
...
... - 10
Process data Bus Out
S
0000 ... FFFF (hex)
This parameter provides information about the actual status word and the actual values that are
transferred via the bus systems.
...
-
01
= Status Word
Status word, source from P509.
... - 02 =
Actual value 1 (P543)
... - 03
= Actual value 2 (P544)
...
-
04
= Actual value 3 (P545)
... - 05
= Bus I/O In Bits (P481)
The displayed value depicts all Bus Out Bit sources
linked with
or
.
... - 06 =
Parameter data Out 1
... - 07 =
Parameter data Out 2
... - 08 =
Parameter data Out 3
... - 09 =
Parameter data Out 4
... - 10 =
Parameter data Out 5
Data during parameter transfer.
P742 Database
version
S
0 ... 9999
Displays the internal database version of the FI.
P743 Inverter
type
0.25 ... 11.00
Displays the inverter power in kW, e.g. "1.50"
FI with 1.5 kW nominal power.