73
Chapter 4
Communications Specification
4
Message
Variable
S2F35
S2F37
S6F11
S6F15
CEID
Format: 52
(2-byte integer)
Constant
Format
5-11. CEID
Collected Event ID
Transmits notification of a processing state change
important for the host. An even-numbered ID
represents a normal change, while an odd-
numbered ID represents an abnormal change. For
the same incident, notification of this ID is sent
independent of the alarm ID, if any.
In maintenance mode, the system operates offline,
and no collection events occur.
CEID 0020 and 0022 occur with ROM version 2.10 or
later when the NWL is connected to the remote box.
[Events Related to Changes in Operational Mode
(Security)]
<Meaning>
<Default Setting>
0002 = Initial routine starts.
OFF
0004 = Wafer is detected during initial routine.
ON
0005 = More than 2 wafers are detected during
the initial routine.
ON
0006 = Initial routine ends.
OFF
0008 = Enters operator mode.
OFF
0010 = Enters engineer mode.
OFF
0020 = Enters remote box mode.
OFF
0022 = Exits remote box mode.
OFF
[Events Related to Changes in Carrier and Wafer
Transfer]
0100 = Cassette is installed.
OFF
0102 = Cassette is removed.
OFF
0200 = Wafer has moved into Surface
macro position.
OFF
0300 = Wafer has moved into Back Side
Edge Macro position.
OFF
0400 = Wafer has moved into Back Side
Center Macro position.
OFF
0450 = Wafer has moved into Surface PS
position.
OFF
0500 = Stage sensor is ON.
OFF
0502 = Stage sensor is OFF.
OFF
0504 = Wafer has moved onto the stage.
OFF
0510 = Wafer has moved onto the change arm
from the stage.
OFF
[Events Related to Progress of Inspection]
0600 = Lot inspection starts.
OFF
0602 = Wafer is accepted.
OFF
0604 = Wafer is rejected in Macro inspection.
OFF
0606 = Wafer is rejected in Micro inspection.
OFF
Summary of Contents for NWL860 Series