82
Chapter 4
Communications Specification
4
Message
Variable
S2F36
LRACK
Link report acknowledge code, 1 byte
0 = Accepted
1 = Denied: Not enough space
2 = Denied: Ineffective format
3 = Denied: At least one CEID link is already
defined.
4 = Denied: At least one CEID doesn’t exist.
5 = Denied: At least one RPTID doesn’t exist.
>5 = Other errors
6–63 = Reserved
Format: 10
(Binary)
Constant
Format
5-31. LRACK
Message
Variable
S2F42
HCACK
Host command/parameter acknowledge code, 1 byte
Response to host command
0 = Acknowledge: The command has been
implemented.
1 = Reject: The command doesn’t exist.
2 = Reject: The command can’t be implemented at
this point.
3 = Reject: At least one parameter is disabled.
4 = Acknowledge: The command has been
implemented, and completion notification is
sent by event report.
5 = Reject: The equipment is already in the state
requested.
Format: 10
(Binary)
Constant
Format
5-32. HCACK
Message
Variable
S1F2
MDLN
Equipment model name, 6 bytes at max.
Model name: “NWL860”
Format: 20
(ASCII)
Constant
Format
5-33. MDLN
Message
Variable
S9F13
MEXP
SxxFyy of a message to receive
Format: 20
(ASCII)
Constant
Format
5-34. MEXP