74
Chapter 4
Communications Specification
4
Message
Variable
S2F35
S2F37
S6F11
S6F15
CEID
Format: 52
(2-byte integer)
Constant
Format
0608 = Pause
OFF
0610 = Pause canceled.
OFF
0612 = Inspection of one item is completed.
OFF
Occurs on completion of:
• Surface Macro inspection
• Back Side Edge Macro inspection
• Back Side Center Macro inspection
• Surface PS inspection
• Micro inspection
0614 = One wafer inspection begins.
OFF
0616 = One wafer inspection is completed.
OFF
0618 = Lot inspection is completed.
OFF
0620 = Lot inspection is forcibly terminated.
OFF
0622 = Mapping is completed.
OFF
0624 = Wafer ejection is completed.
OFF
0626 = Immediate stop is completed.
OFF
0628 = An error occurs.
OFF
Refers to errors defined by ALID.
0630 = An error is canceled.
OFF
0632 = Height/pitch measurement is
completed.
OFF
[Events Related to File Management]
0800 = Data for a sample file is changed
(STORE).
OFF
Occurs when the change is saved.
0802 = Data for a carrier file is changed
(STORE).
OFF
Occurs when the changes is stored.
0804 = Another sample file is selected for
implementation.
OFF
0808 = Another carrier file is selected for
implementation.
OFF
0810 = Equipment setting(s) is changed.
OFF
0812 = Data for a sample file is changed
(temporary).
OFF
Occurs when changes are made,
or during temporary inspections.
[Events Related to Control Mode]
0900 = Shifts to offline mode.
OFF
0902 = Shifts to online local mode.
OFF
0904 = Shifts to online remote mode.
OFF
[Events Related to Indexer]
9000 = Indexer self-check is completed.
OFF
9001 = Indexer self-check is completed
(abnormal).
OFF
9002 = Indexer pod has been locked.
OFF
9003 = Indexer pod has been locked
(abnormal).
OFF
9004 = Indexer pod has been unlocked.
OFF
Summary of Contents for NWL860 Series
Page 1: ...M232 E 04 7 CF 3 Wafer Loader NWL860 Series IFC Function SECS Communications Specifications ...
Page 3: ......