79
Chapter 4
Communications Specification
4
Message
Variable
S2F13
S2F15
S2F29
S2F30
ECID
Format: 51
(1-byte integer)
Constant
Format
022 = SECSDEVID
ECNAME = SECS_DEVID
ECV: Format 52 (2-byte integer)
Range:
0–32767
Setting unit: 1
Default = 101
023 = SECST1 (character to character time-out)
ECNAME = SECS_T1
ECV: Format 51 (1-byte integer)
Range:
1–100 (0.1–10 seconds)
Setting unit: 1 (0.1 seconds)
Default = 5 (0.5 seconds)
024 = SECST2 (protocol time-out)
ECNAME = SECS_T2
ECV: Format 51 (1-byte integer)
Range:
1–125 (0.2–25 seconds)
Setting unit: 1 (0.2 seconds)
Default = 50 (10 seconds)
025 = SECST3 (Response time-out)
ECNAME = SECS_T3
ECV: Format 51 (1-byte integer)
Range:
1–120 (1–120 seconds)
Setting unit: 1 (1 second)
Default = 45 (45 seconds)
026 = SECST4 (block to block time-out)
ECNAME = SECS_T4
ECV: Format 51 (1-byte integer)
Range:
1–120 (1–120 seconds)
Setting unit: 1 (1 second)
Default = 45 (45 seconds)
027 = SECS retry
ECNAME = SECS_RTY
ECV: Format 51 (1-byte integer)
Range:
0–31 (0–3 times)
Setting unit: 1 (once)
Default = 3 (3 times)
028 = Establishment of Communications time-out
ECNAME = ECD
ECV: Format 51 (1-byte integer)
Range:
1–120 (10–1200 seconds)
Setting unit: 1 (10 seconds)
Default = 1 (10 seconds)
041 = Programmable stop
ECNAME = SET_PS
ECV: Format 51 (1-byte integer)
0 = Off
1 = On
Default = 0