85
Chapter 4
Communications Specification
4
Message
Variable
S2F41
RCMD
Format: 20
(ASCII)
Constant
Format
Content: PPID of the carrier file to implement
When the command is enabled, collection event
CEID = 0804 or 0808 occurs.
<STOP>
Completes the ongoing sequence of operations to
finish a lot.
(Equivalent to selecting End after the key-initiated
pause.)
Command Parameter: Not Required
When the command is enabled, collection event
CEID = 0620 occurs.
<PAUSE>
Equivalent to key-initiated pause. (Resumable)
Command Parameter: Not Required
When the command is enabled, collection event
CEID = 0608 occurs.
<RESUME>
Equivalent to resuming after key-initiated pause.
Command Parameter: Not Required
When the command is enabled, collection event
CEID = 0610 occurs.
<ABORT>
Immediately halts operation. (Not resumable)
Command Parameter: Not Required
When the command is enabled, collection event
CEID = 0626 occurs.
<ERR_RECOVER>
Sends notification that the error cause has been
resolved and instructs the equipment to resume
interrupted operations.
Command Parameter: Not Required
When the command is enabled, collection event
CEID = 0630 occurs.
<ACCEPT>
Equivalent to pressing the Accept key (OK, NEXT).
Does not have start function. Enabled when the
processing status is inspecting.
Command Parameter: Not Required
When the command is enabled, collection event
CEID = 0602 occurs.
<MIC_NG>
Equivalent to pressing the Microscope Reject key;
enabled only when a Micro inspection is underway.
●
When the reject type is not specified, a list of
zero length follows MIC_NG.
●
When the reject type is specified:
CPNAME = NG_TYPE
CPVAL Format: 20 (ASCII) one character
Content: 1–9