80
Chapter 4
Communications Specification
4
Message
Variable
S2F13
S2F15
S2F29
S2F30
ECID
Format: 51
(1-byte integer)
Constant
Format
042 = Programmable stop time
ECNAME = PS_TIME
ECV: Format 31 (1-byte integer with sign)
-1–99 (second)
-1 = Infinite Setting unit: 1 (1 second)
Default = -1
043 = Programmable stop angle
ECNAME = PS_ROT
ECV: Format 32 (2-byte integer with sign)
0,45,90,135,180,225,270,315 (degree)
Default = 0
Message
Variable
S2F30
ECMAX
Maximum value of equipment constants
See ECV ranges in “5-21. ECID” above. Format
codes vary, depending on ECV.
Depends on ECID.
Constant
Format
5-22. ECMAX
Message
Variable
S2F30
ECMIN
Minimum value of equipment constants
See the ECV ranges in “5-21. ECID” above. Format
codes vary, depending on ECV.
Depends on ECID.
Constant
Format
5-23. ECMIN
Message
Variable
S2F30
ECNAME
Text data for equipment constant names
See “5-21. ECID” above.
Format: 20
(ASCII)
Constant
Format
5-24. ECNAME
Message
Variable
S2F14
S2F15
ECV
Value of equipment constants
See “5-21. ECID” above.
Depends on ECID.
Constant
Format
5-25. ECV