33
Chapter 4
Communications Specification
4
3-8.
Remote Control
Remote control of equipment from the host is performed through transmission of commands from the
host and corresponding event reports from equipment.
(Examples: Changes in current PPID, startup, stop, and individual operation (mapping))
<Scenario>
○
Remote control
Message: S2F41,F42,S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
Transmits a command.
S2F41
→
←
S2F42
Acknowledges the host command.
[IF]
The command is accepted (HCACK = 0, 4);
←
S6F11
[THEN] Event report of changes in status or other
collection events.
Acknowledges event report.
S6F12
→
3-9.
Alarm Management
When a problem included in the preset alarm conditions by the host occurs, the equipment sends
notification to the host of the alarm.
Alarm notification is transmitted separately from event reports.
3-9-1.
Alarm Enable/Disable Setting
The host sets the alarms for which the equipment should transmit notification.
<Scenario>
○
Alarm enable/disable
Message: S5F3,F4
<Comment>
[Host]
[Equipment] <Comment>
Transmits the alarm enable/disable setting.
S5F3
→
←
S5F4
Acknowledges the setting.
3-9-2.
Alarm Information Uploading
<Scenario>
○
Alarm information uploading
Message: S5F5,F6
<Comment>
[Host]
[Equipment] <Comment>
Requests alarm data/text.
S5F5
→
←
S5F6
Transmits alarm data/text.
3-9-3.
Alarm Report Transmission
The equipment detects the occurrence of an alarm.
<Scenario>
○
Alarm report transmission
Message: S5F1,F2
<Comment>
[Host]
[Equipment] <Comment>
←
S5F1
Transmits alarm data/text.
Acknowledges alarm data/text.
S5F2
→
(Transmits event report, if the alarm is enabled.)