56
5. Settings
Digitax SF I
nstruction Man
ual
5. Parameters
No. 114.0
Tuning:
Position control mode - Control level
Range
Default
Characteristics
5 to 45
15
Function
Use
Set the Control Level of Position Control Mode.
With this parameter, both
Control Gain 1
(115.0) and
Control Gain 2
(116.0) can be set to
pairs of
preset values.
In
Digitax SF Connect
, set this parameter under the [Waveform Monitor] tab.
Noise Solutions
①
Use
Torque command filter: Notch filter
(such as 160.1).
②
Decrease
Position control mode - Integral gain
(119.0).
③
Decrease
Position control mode - Control gain 2
(116.0).
If any of the above does not work, decrease the Control Gain Set value.
Setting
Command Response Rigidity
Settling Time
Possibility of Noise
5
slower
lower
longer
lower
↑
↑
↑
↑
↑
↓
↓
↓
↓
↓
45
faster
higher
shorter
higher
Prerequisite
Position Control Mode
Remark
・Setting Control Level will invalidate the setting of
Control gain set
(113.0).
・The specified values of
Control Gain 1
(115.0) and
Control Gain 2
(116.0) vary depending
on
Inertia conditions
(113.1).
Related To
No. 113.0, No. 113.1, No. 115.0, No. 116.0
7
Tuning
-
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...