11
4
Connection
Digitax SF
Instruction Manual
2
.
Position Control Mode
4.
Connection
s
2.
Position Control Mode
1: 24 V
24 V
GND
24 V
G24 V
2: G24 V
3: COM+
4: SVON
5: RESET
6: HOLD
7: PCLR
9: CCWL
10: CWL
11: TLSEL1
12: COM-
13: MBRK
14: SERVO
15: POSIN
17: T-LIMIT
18: OCZ
19: SRDY+
20: SRDY-
21: ALM+
22: ALM-
28: CC-P
FG
36: OUT_A
37: /OUT_A
38: OUT_B
39: /OUT_B
40: OUT_Z
41: /OUT_Z
43: 485
44: /485
45: SG
42: SG
27: /CMD_PLS
29: CC-D
31: /CMD_DIR
SG
2.2 k
Ω
Control power supply 24 V input
Control power supply GND
I/O power supply 24 V input
INPUT
䚷
Servo ON
INPUT
䚷
Alarm reset
INPUT
䚷
Command input
inhibition
㻵㻺㻼㼁㼀䚷
Position error
㻌㼏㼛㼡㼚㼠㼑㼞
䚷䚷䚷䚷䚷䚷㼏㼘㼑㼍㼞
INPUT
䚷
CCW run
limit switch
input
INPUT
䚷
CW run
limit switch
input
I/O power supply GND
OUTPUT
䚷
Motor
Brake
release
OUTPUT
䚷
Positioning
complete
OUTPUT
䚷
Servo state
OUTPUT Under torque
limit
OUTPUT
䚷
Encoder Z-phase
䠄
open-collector
䠅
OUTPUT
䚷
Servo-Ready+
OUTPUT
䚷
Servo-Ready-
OUTPUT
⅙
Alarm State+
OUTPUT
䚷
Alarm State-
Pulse Train
Command Input
A-phase
output
B-phase
output
Z-phase
output
Pulse
RS-422 output
2 m or
shorter
Twisted Pair Cable
Frame
Encoder Signal Output
Direction
Control Power
Shielded
㻖
3
㻖
1
㻖
1
㻖
1
㻖
1
㻖
2
㻖
6
㻖
4
㻖
5
Servo
Drive
4.7 k
Ω
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
2.2 k
Ω
SG
SG
Shielded
24 V
24 V
Host SG
SG
SG
Host SG
RS-485
Host Controller
SG
㻖
5
㻖
4
*1) Control power (24V, G24V) and power for I/O (COM+, COM-) must share one common power supply.
*2) When driving a load containing inductance
(
component such as
a
relay
)
connect a protection circuit (diode).
The motor brake cannot be driven directly. Be sure to use a circuit that interfaces with a diode built-in type relay.
Page 46 Connection to general-purpose output signals
*3) The output circuit configuration is an open collector Darlington transistor output. Connects to relays and optical isolators.
Note that when the transistor is on, connector-emitter voltage VCE (SAT) is approximately 1V;
a standard TTL IC does not satisfy VIL and cannot be connected directly.
*4) Be sure to connect a termination resistor of approximately 220 Ω .
*5) Make the connection to the communication IC signal ground of the host controller that
the drive
encoder output signals
are connecting to. Connecting signal ground SG to control power GND may result in malfunction.
*6) If Z-phase pulse width is too small to be measured accurately by the host controller, decrease pulse division rate by using pulse output
ratio (parameters No.276.0 and No.278,0) or decrease rotational speed to increase the pulse width.
Pulse width [ms] = 2 / rotational speed [
rpm
] / (division ratio × 2
17
) × 60 × 1,000.
Pulse Train Command, 24V Open Collector, Standard I/O Configuration
CN1 Connector Wiring Example
24
INPUT Torque limit
selection
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...