70
5. Settings
Digitax SF I
nstruction Man
ual
5. Parameters
No. 226.0
Deceleration stop:
Operating time
Range
Default
Characteristics
0 to 16,383
(See below)
Function
Use
This parameter
defines the
deceleration stop operation time
when
an alarm
occurs or the Servo ON signal turns OFF. It is used for a motor which is slowing
down as specified with the deceleration stop method (224.0).
Motor Capacity
Default
Units
Converted to Time
50 W to 750 W
313
160 µs
50 [ms]
1 kW to 2 kW
250
200 µs
Prerequisite
Deceleration stop Method (upon servo off)(224.0) = 1 (Short brake) or 2 (Quick stop))
Related To
No. 224.0, No. 224.1, No. 227.0
No. 227.0
Deceleration stop:
Cancellation speed
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter
defines the
rotational speed to cancel deceleration-stop in case an
alarm occurs or the Servo ON signal turns OFF.
It is used for a motor which is slowing down as specified with the deceleration stop method (224.0).
Motor Capacity
Default
Units [encoder pulse]
Conversion to Rotational Speed
50 W to 750 W
17
pulse/160 µs
50 [
rpm
]
1 kW to 2 kW
22
pulse/200 µs
Prerequisite
Deceleration stop: Method (224.0) = 1 (Short brake) or 2 (Quick stop)
& Deceleration stop: Release conditions (224.1) = 1
Related To
No. 224.0, No. 224.1, No. 226.0
No. 228.0
Deceleration stop:
Operating time
(upon control power error)
Range
Default
Characteristics
0 to 16,383
(See below)
Function
Use
Set Deceleration stop time in the event
an
alarm
condition
due to a
AC Supply loss
.
Motor Capacity
Default
Units
Converted to Time
50 W to 750 W
62
160 µs
10 [ms]
1 kW to 2kW
52
200 µs
Prerequisite
Deceleration stop: Switch (upon
AC Supply
loss
) (224.2) = 1 (Enable)
Related To
No. 224.2
-
-
-
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...