No. 70.0
Positioning complete:
Detection criteria - Command Input
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
Set the value for a pulse train command input (Speed) to determine Positioning
Complete.
Motor Capacity
Default
units[encoder pulse] Conversion to Rotational Speed
50 W to750 W
0
pulse/160 µs
0 [
rpm
]
1 kW to 2 kW
0
pulse/200 µs
0 [
rpm
]
Velocity
Velocity Command
0
The setting value of No.70.0
Time
Positioning Complete
When position
in
g is complete, the signal POSIN (positi
o
ning complete) will be output to the
host controller.
No. 71.0
Positioning complete:
Detection delay time
Range
Default
Characteristics
0 to 65,000
(See below)
Function
Use
Specify the delay time to output Positioning Complete signal (POSIN) to the host
controller after Positioning Complete conditions are met.
Motor Capacity
Default
Units
Conversion to Time
50 W to 750 W
20
160 µs
3.2 [ms]
1 kW to 2 kW
16
200 µs
3.2 [ms]
Detection delay time
ı
Position
Error
Time
Positioning Complete
Range
Positioning Complete
Related To
No. 64.0, No. 68.0, No. 69.0, No. 70.0
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...