28
9. Appendices
Digitax SF
Instruction Manual
4. Status Display
Status
Regeneration Status
Units
Bytes
Signed
Status No.
(Hexadecimal number)
228 (E4)
-
2
no
Description
This item indicates the regeneration status of the
. Drive
power circuit.
Setup Panel
5
Settings Setup Panel
Digitax SF Connect
【waveform monitor】displays total value of I/O bits in decimal.
【status monitor】displays I/O bits in binary.
Transmit data
24 01 00 10 00 E4 69 21
Status
Power Circuit Supply
Voltage
Units
Bytes
Signed
Status No.
(Hexadecimal number)
232 (E8)
0.1 V
2
no
Description
Indicates the
power circuit
supply
voltage (for reference only).
Transmit data
24 01 00 10 00 E8 A8 AD
Relations between RS-485 Communication Command and Bit Tables
ー
15
Transmit data:
Response data:
Error detection
Regeneration
Status
14 13 12 11 10 9 8 7
5 4 3 2 1 0
0/1
ー
ー
ー
ー
ー
ー
ー
0/1
0/1
ー
ー
ー
ー
ー
bit
(byte)
(byte)
24
01
00
10
00
E4
69
21
24
01
80
10
〔・・〕〔・・〕
Output
Input
Regeneration control output
9
8
0
Output
Input
6
Regeneration voltage warning
・・・1: Being output
Name and Meaning
Decimal
0
256
512
** **
Indicates the operation status of the regenerative power processing circuit.
Indicates the voltage has reached the warning level.
You need to
connect a
braking
resistor to the
drive
.
Regeneration voltage threshold
Indicates the voltage has reached the threshold.
A power error, or
, will occur if the
braking
resistor is not connected.
bit
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...