
23
Digitax SF
I
nstruction Manual
Operation
6
6. Operation
5. Position Control Mode
5.
Position Control Mode
Item
Positioning complete
Range
Units
0 to 32,767
[ pulse ]
Description
Set a position
error
threshold to determine whether or not positioning is complete.
After the motion specified by the point number has been complete, when the position
error
falls
in the range set by this
parameter
and then the Dwell time elapses, the MEND (motion end)
signal turns ON.
Timing Diagram (Positioning complete and Dwell time)
Signal Name
Description
Chart
−
−
Input
PCSEL1…4
Input
(Output)
MEND
PCSTART1
ON
OFF
Motion
Complete
OFF
0 [
rpm
]
0 [pulse]
ON
OFF
ON
1
Actual motion
Command
Dwell Time
Positioning Complete
Select
Point No.
Start
Motor
Rotational
Speed
Position
Error
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...