23
3. Preparation
Digitax SF Instruction Manual
2. System Wiring
Cable Name
AWG
UL
Temperature
Rating
Voltage
Rating
Note
Motor power
(
≤
750 W)
18
2517
105 ℃
300 V
Motor power
(
≥
1 kW)
14
2517
105 ℃
300 V
AWG16 wires can be used only for 1 kW
motors
Main circuit power
(
≤
750 W)
( Including
Earth/
Ground
FG cable )
18
1015
105 ℃
600 V
Main circuit power
(
≥
1 kW)
( Including
Earth/
Ground
FG cable )
14
1015
105 ℃
600 V
AWG16 wires can be used only for 1 kW
motors.
Encoder
Power:22
Signal:24
20276
80 ℃
30 V
Shielded twisted pair cables of length
no
t
exceeding 20 m
User I/O
26
1007
80 ℃
300 V
Shielded twisted pair cables
Length not exceeding 2 m is recommended
Braking
resistor
18
1015
105 ℃
600 V
Emergency stop
brake
18
1015
105 ℃
600 V
Mechanical
Brake
18
2517
105 ℃
300 V
1 pair (2 cores)
Use our recommendations below to select cables based on your actual usage. (Equivalent alternatives are also
good)
5. Cables
Recommended cable wires
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...