23
9
9. Appendices
Digitax SF
Instruction Manual
Appendices
4.
Status Display
4. Status Display
Status
Position
Error
Units
Bytes
Signed
Status No.
(Hexadecimal number)
69 (45)
encoder pulse
4
yes
Description
Indicates
error
between the position command and position feedback.
This value is important for tuning in position control mode, enabling you to do the following:
To check the positioning time—for the position
error
to settle into your desired range after
the pulse train command became 0—and vibration.
To adjust gains such that the positioning time will be shorter and vibration will be suppressed,
so the specifications for the equipment will be satisfied
To check resonant frequency, in case of equipment vibration, by using waveforms of position
error
or torque limit value.
To see whether vibration was suppressed by checking waveforms after specifying the vibration
frequency for the following position command filters.
・
Filter 1 (Smoothing filter 1) Moving average counter
(80.0)
・
Filter 4 (Smoothing filter 2) Moving average counter
(81.0)
Transmit data
24 01 00 11 00 45 FB DA
Status
ABS Position Command
Units
Bytes
Signed
Status No.
(Hexadecimal number)
74 (4A)
command pulse
4
yes
Description
This indicates a position command value based on the home-position offset.
Transmit data
24 01 00 11 00 4A 0A 35
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...