1 Menu tree
1.4 MAIN MENU – Config
130
FST_HB.EN04/03
Maximum loading time
The maximum loading time in seconds can be set in
Load Time-max.
.
Load-Sw.Disp
FPM output “Display-1” (X4.38) can display the loading function if
Load-
Sw.Disp
=
YES
. The display starts flashing 20 sec before the maximum
loading time has elapsed (see “Display-0 … 2” on page 128).
Lobby-Stop
With the function “Lobby-Stop” enabled the car does not pass the
selectable “Lobby” floor. The car always stops so the employees have the
possibility to look in the car.
This function provides the following options:
Enable
The function „Lobby-Stop” is activated in
Enable
.
Floor
The “Lobby” floor is set in
Floor
.
Doors
The car doors to be opened in the “Lobby” floor are set in
Doors
.
V.I.P. Mode
The V.I.P. Mode can be used the dedicate a car to “very important people”.
There are two V.I.P Modes:
-
V.I.P. Mode 1 : Triggered by the LMS or a programmable input/output.
Sets all call buttons to “dead man mode”.
-
V.I.P. Mode 2 : Triggered by FPM input X4.34 (key switch in the car),
has the functions described below.
V.I.P. Mode 2
-
Triggered by an impulse on FPM input X4.34 (key switch or card
reader).
-
All pending landing calls are deleted and the landing control is locked.
-
Group operation: the lift is removed from the group and returns all
pending landing calls to the group control.
-
An in-car call must be placed within ten seconds of activation, otherwise
the lift will return to normal mode.
-
All in-car calls already registered at the time of activation will be
executed as usual.
-
In “multiple call” mode an unlimited number of in-car calls can be placed
(see “Pin-34 Functn” on page 129). This way the V.I.P. Mode can be
Summary of Contents for FST
Page 1: ...Manual Field Bus Controller ...
Page 6: ...Table of Contents 4 FST_HB EN04 03 ...
Page 43: ...4 Technical Data 4 2 FST Controller FST_HB EN04 03 41 Fig 4 2 FST Controller ...
Page 98: ...4 Technical Data 4 13 Trailing cable 96 FST_HB EN04 03 Fig 4 14 Trailing cable version 1 ...
Page 102: ...4 Technical Data 4 13 Trailing cable 100 FST_HB EN04 03 ...
Page 104: ...1 Menu tree 1 1 General 102 FST_HB EN04 03 Fig 1 1 FST Controller menu tree part 1 ...
Page 105: ...1 Menu tree 1 1 General FST_HB EN04 03 103 Fig 1 2 FST Controller menu tree part 2 ...
Page 106: ...1 Menu tree 1 1 General 104 FST_HB EN04 03 Fig 1 3 FST Controller menu tree part 3 ...
Page 107: ...1 Menu tree 1 1 General FST_HB EN04 03 105 Fig 1 4 FST Controller menu tree part 4 ...
Page 108: ...1 Menu tree 1 1 General 106 FST_HB EN04 03 Fig 1 5 FST Controller menu tree part 5 ...
Page 109: ...1 Menu tree 1 1 General FST_HB EN04 03 107 Fig 1 6 FST Controller menu tree part 6 ...
Page 110: ...1 Menu tree 1 1 General 108 FST_HB EN04 03 Fig 1 7 FST Controller menu tree part 7 ...
Page 111: ...1 Menu tree 1 1 General FST_HB EN04 03 109 Fig 1 8 FST Controller menu tree part 8 ...
Page 112: ...1 Menu tree 1 1 General 110 FST_HB EN04 03 Fig 1 9 FST Controller menu tree part 9 ...
Page 160: ...6 Error List 6 4 Error messages 158 FST_HB EN04 03 ...