1 Menu tree
1.4 MAIN MENU – Config
FST_HB.EN04/03
125
Landing buttons
ADM-EAZ type
Position indicator code issued by ADM X3.
-
HEX: Binary code
-
1-of-N: Separate signal for each floor (only possible up to a
maximum of five floors)
-
GRAY: Gray Code
The initial value for the bottom floor can be set in
Bottom
Flr. Hall
(see “Bottom Flr. Hall” on page 120).
HEX
GRAY
1-of-N
Landing buttons
Special Display 0
Function of terminal 14 of the ADM-S landing button module
(the function of terminal 14 must be set to “Soft-1” in the FST-
Editor).
0: No function
1: “Door open” display for revolving doors
2: Fireman Mode active
3: Priority car or landing active
4: Fireman Mode or fire signal active
5: Out-of-use (display only when the system is
shut down)
6: Priority car active
0 .. 255
Landing buttons
Special Display 1
No function at present
0 .. 255
Lift-Off
Lift-Off Program
There can be more than one input for remote shutdown.
-
FST X7.14
-
ADM X3
-
RIO Module
-
GST (see GST Manual)
After activating one of the inputs the controller triggers a “hard”
or “soft” remote shutdown drive to the remote shutdown floor.
Then the car light is switched off and the system is shut down.
The door open button on the in-car panel remains active!
-
HARD: All in-car and landing calls are deleted.
-
SOFT: In-car calls remain, landing calls are deleted.
HARD
SOFT
Lift-Off
Lift-Off Floor
Target floor of the remote shutdown drive.
0 ... 63
Lift-Off
Lift-Off Doors
The door set here will be opened and closed again after the
remote shutdown drive before the car light is switched off.
All doors
Door A only
Door B only
Door C only
Special Functions
Loading Function
Activate the special “Loading Function” (see “Loading
Function” on page 129).
Special Functions
Lobby-Stop
Activate the special function “Lobby-Stop” (see “Lobby-Stop”
on page 130).
Special Functions
Attika Control
Activate the special function “Attika Control” (see System
description – Attika Control).
Special Functions
Bank-Control
Activate the special function “Bank-Control” (see System
description – Bank-Control).
Special Functions
Ramp-Drive
Activate the special function “Ramp-Drive” (see System
description – Ramp-Drive).
Blinking Approach
The indicator lights for in-car and landing calls flash when
approaching the target floor.
YES
NO
Insp. Door Test
Enable door open/door close buttons (see “FPM: X4” on
page 69) for moving the doors in dead man control. Door
open/door close buttons can be installed on the car roof and
wired parallel to the buttons of the in-car panel.
YES
NO
Menu item
Description
Setting range
Summary of Contents for FST
Page 1: ...Manual Field Bus Controller ...
Page 6: ...Table of Contents 4 FST_HB EN04 03 ...
Page 43: ...4 Technical Data 4 2 FST Controller FST_HB EN04 03 41 Fig 4 2 FST Controller ...
Page 98: ...4 Technical Data 4 13 Trailing cable 96 FST_HB EN04 03 Fig 4 14 Trailing cable version 1 ...
Page 102: ...4 Technical Data 4 13 Trailing cable 100 FST_HB EN04 03 ...
Page 104: ...1 Menu tree 1 1 General 102 FST_HB EN04 03 Fig 1 1 FST Controller menu tree part 1 ...
Page 105: ...1 Menu tree 1 1 General FST_HB EN04 03 103 Fig 1 2 FST Controller menu tree part 2 ...
Page 106: ...1 Menu tree 1 1 General 104 FST_HB EN04 03 Fig 1 3 FST Controller menu tree part 3 ...
Page 107: ...1 Menu tree 1 1 General FST_HB EN04 03 105 Fig 1 4 FST Controller menu tree part 4 ...
Page 108: ...1 Menu tree 1 1 General 106 FST_HB EN04 03 Fig 1 5 FST Controller menu tree part 5 ...
Page 109: ...1 Menu tree 1 1 General FST_HB EN04 03 107 Fig 1 6 FST Controller menu tree part 6 ...
Page 110: ...1 Menu tree 1 1 General 108 FST_HB EN04 03 Fig 1 7 FST Controller menu tree part 7 ...
Page 111: ...1 Menu tree 1 1 General FST_HB EN04 03 109 Fig 1 8 FST Controller menu tree part 8 ...
Page 112: ...1 Menu tree 1 1 General 110 FST_HB EN04 03 Fig 1 9 FST Controller menu tree part 9 ...
Page 160: ...6 Error List 6 4 Error messages 158 FST_HB EN04 03 ...