1 Menu tree
1.5 MAIN MENU – Positioning
132
FST_HB.EN04/03
1.5 MAIN MENU – Positioning
All menu items with adjustable values can be deactivated by entering the
value “0”.
Menu item
Description
Setting range
Floor –
Position ABS
Absolute levelling position of a floor. Do not change this value
(see Installation & Commissioning).
0 ... 9999999 mm
Floor –
Position REL
Levelling position of a floor relative to the bottom floor. This
value is entered for each floor according to the system
drawing or determined automatically during the learn drive
(see Installation & Commissioning).
-2500 ... 250000 mm
Floor –
Level UP
Switch-on point for the internal levelling signal below the
actual levelling position when moving up. This value
corresponds to the braking distance of the crawling speed
upwards and is determined automatically during the
calibration drive (see Installation & Commissioning).
0 ... 5000 mm
Floor –
Level DOWN
Switch-on point for the internal levelling signal above the
actual levelling position when moving down. This value
corresponds to the braking distance of the crawling speed
downwards and is determined automatically during the
calibration drive (see Installation & Commissioning).
0 ... 5000 mm
Floor –
Zone Sw.UP
Switch-on point for the internal door zone signal above the
actual levelling position.
Linear positioning: Set value to 200 mm!
Incremental positioning: Do not change value determined
automatically during the learn drive! (See Installation &
Commissioning.)
0 ... 2500 mm
Floor –
Zone Sw.DOWN
Switch-on point for the internal door zone signal below the
actual levelling position.
Linear positioning: Set value to 200 mm!
Incremental positioning: Do not change value determined
automatically during the learn drive! (See Installation &
Commissioning.)
0 ... 2500 mm
Landing –
Landing UP
Approach distance of the different drive speeds V1 … V8
when moving upwards. The values correspond to the braking
distance for each speed when moving up. The values are
determined automatically during the calibration drive. (See
Installation & Commissioning.)
0 ... 99999 mm
Landing –
Landing DOWN
Approach distance of the different drive speeds V1 … V8
when moving upwards. The values correspond to the braking
distance for each speed when moving down. The values are
determined automatically during the calibration drive. (See
Installation & Commissioning.)
0 ... 99999 mm
Global –
Resolutn.
Resolution of the absolute value encoder. This value
determines how many bits are sent by the encoder for each
millimetre of car movement. If this value is set incorrectly the
distances between floors are wrong and the car can hit the
limit switch at full speed during the calibration drive (see
Installation & Commissioning).
0 ... 999,9999 bit/mm
Global –
Direction
Direction of rotation of the absolute value encoder.
Left
Right
Summary of Contents for FST
Page 1: ...Manual Field Bus Controller ...
Page 6: ...Table of Contents 4 FST_HB EN04 03 ...
Page 43: ...4 Technical Data 4 2 FST Controller FST_HB EN04 03 41 Fig 4 2 FST Controller ...
Page 98: ...4 Technical Data 4 13 Trailing cable 96 FST_HB EN04 03 Fig 4 14 Trailing cable version 1 ...
Page 102: ...4 Technical Data 4 13 Trailing cable 100 FST_HB EN04 03 ...
Page 104: ...1 Menu tree 1 1 General 102 FST_HB EN04 03 Fig 1 1 FST Controller menu tree part 1 ...
Page 105: ...1 Menu tree 1 1 General FST_HB EN04 03 103 Fig 1 2 FST Controller menu tree part 2 ...
Page 106: ...1 Menu tree 1 1 General 104 FST_HB EN04 03 Fig 1 3 FST Controller menu tree part 3 ...
Page 107: ...1 Menu tree 1 1 General FST_HB EN04 03 105 Fig 1 4 FST Controller menu tree part 4 ...
Page 108: ...1 Menu tree 1 1 General 106 FST_HB EN04 03 Fig 1 5 FST Controller menu tree part 5 ...
Page 109: ...1 Menu tree 1 1 General FST_HB EN04 03 107 Fig 1 6 FST Controller menu tree part 6 ...
Page 110: ...1 Menu tree 1 1 General 108 FST_HB EN04 03 Fig 1 7 FST Controller menu tree part 7 ...
Page 111: ...1 Menu tree 1 1 General FST_HB EN04 03 109 Fig 1 8 FST Controller menu tree part 8 ...
Page 112: ...1 Menu tree 1 1 General 110 FST_HB EN04 03 Fig 1 9 FST Controller menu tree part 9 ...
Page 160: ...6 Error List 6 4 Error messages 158 FST_HB EN04 03 ...