1 Menu tree
1.5 MAIN MENU – Positioning
FST_HB.EN04/03
135
Positioning Parameters
For a better understanding of the parameters for linear and incremental
positioning the main settings are shown graphically in the following two
figures.
Increm. Positng. –
Auto-Orien.
With incremental positioning an orientation drive to the top or
bottom landing is required after switching the controller on and
off (also after a power failure). The orientation drive is started
automatically after switching the FST-Controller on. Only
change this parameter after consulting NEW LIFT!
YES
NO
Increm. Positng. –
Orien delay
Delay of the orientation drive after switching the FST-
Controller on.
0 ... 9999 ms
Increm. Positng. –
Corr.Bottom
Position of the switch for bottom correction in [mm]. This is an
absolute value. To determine the distance to the bottom floor
the absolute value of the bottom floor must be subtracted from
the value entered here (see “Position ABS” on page 132). The
value is determined automatically during the learn drive and
must not be changed!
0 ... 9999999 mm
Increm. Positng. –
Corr.Top
Position of the switch for top correction in [mm]. This is an
absolute value. To determine the distance to the top floor the
value entered here must be subtracted from the absolute
value of the top floor (see “Position ABS” on page 132). The
value is determined automatically during the learn drive and
must not be changed!
0 ... 9999999 mm
Increm. Positng. –
ZoneB–Length
Length of the zone signal when relevelling with the BO/BU
switch. This value is determined automatically during the learn
drive.
0 ... 250 mm
Increm. Positng. –
BOBU<->Runoff
Length of the BO/BU signal when relevelling with the BO/BU
switch. This value is determined automatically during the learn
drive.
0 ... 250 mm
Increm. Positng. –
ZoneB–Hysters
Length of the hysteresis of zone switch B. This value is
determined automatically during the learn drive and is limited
to 10 mm by the software. In case of problems with the
levelling adjustment the levelling for upward travel can be
adjusted as described in the installation manual and the
levelling for downward travel can be adjusted by changing the
hysteresis value.
-100 ... 100 mm
Increm. Positng. –
ZoneB–Level
Level of zone switch B if the car is in the door zone.
-
LO: 0V (closed)
-
HI: +24V (open, default)
The setting must correspond to jumper JMP7 on the FST
circuit board (see “Jumper JMP7” on page 43).
LO
HI
Increm. Positng. –
ZoneB–Debnce
Debounce time of zone switch B. Only change this value after
consulting NEW LIFT!
0 ... 40 msec
Increm. Positng. –
CB/CT–Level
Level of the CB/CT switch if the car is at the top or bottom
landing.
-
LO: 0V DC
-
HI: +24V (default)
The setting must correspond to jumper JMP7 on the FST
circuit board (see “Jumper JMP7” on page 43).
LO
HI
Menu item
Description
Setting range
Summary of Contents for FST
Page 1: ...Manual Field Bus Controller ...
Page 6: ...Table of Contents 4 FST_HB EN04 03 ...
Page 43: ...4 Technical Data 4 2 FST Controller FST_HB EN04 03 41 Fig 4 2 FST Controller ...
Page 98: ...4 Technical Data 4 13 Trailing cable 96 FST_HB EN04 03 Fig 4 14 Trailing cable version 1 ...
Page 102: ...4 Technical Data 4 13 Trailing cable 100 FST_HB EN04 03 ...
Page 104: ...1 Menu tree 1 1 General 102 FST_HB EN04 03 Fig 1 1 FST Controller menu tree part 1 ...
Page 105: ...1 Menu tree 1 1 General FST_HB EN04 03 103 Fig 1 2 FST Controller menu tree part 2 ...
Page 106: ...1 Menu tree 1 1 General 104 FST_HB EN04 03 Fig 1 3 FST Controller menu tree part 3 ...
Page 107: ...1 Menu tree 1 1 General FST_HB EN04 03 105 Fig 1 4 FST Controller menu tree part 4 ...
Page 108: ...1 Menu tree 1 1 General 106 FST_HB EN04 03 Fig 1 5 FST Controller menu tree part 5 ...
Page 109: ...1 Menu tree 1 1 General FST_HB EN04 03 107 Fig 1 6 FST Controller menu tree part 6 ...
Page 110: ...1 Menu tree 1 1 General 108 FST_HB EN04 03 Fig 1 7 FST Controller menu tree part 7 ...
Page 111: ...1 Menu tree 1 1 General FST_HB EN04 03 109 Fig 1 8 FST Controller menu tree part 8 ...
Page 112: ...1 Menu tree 1 1 General 110 FST_HB EN04 03 Fig 1 9 FST Controller menu tree part 9 ...
Page 160: ...6 Error List 6 4 Error messages 158 FST_HB EN04 03 ...