88
Options and programming methods
Do not increase the “VolumeTel. In” parameter excessively, as an excessive value
may cause incorrect interpretation of DTMF tones.
•
If the volume of the telephone messages is low, increase the “Volume Tel.voice” (in
small steps of 1 or 2 units) and verify the effect. An excessive value of the “Volume
Tel.voice.” parameter may cause incorrect interpretation of DTMF tones.
In most cases, the value of the “Volume Tel.voice” parameter is between 15 and 25,
whereas, the value of the “VolumeTel. In.” parameter is between 20 and 30.
If you are not using a SmartLink GSM interface, you should:
•
If the DTMF tones are not recognized or are recognized with difficulty, increase the
“VolumeTel.In” parameter of the SmartLink by 1 or 2 notches over the medium value
“M” then verify the effect. If there is no improvement, decrease the value of the
“VolumeTel.In.” parameter of the SmartLiving control panel until an acceptable
combination is achieved.
Note
Any changes to the value of the SmartLink “VolumeTel.In.” parameter come into effect almost 2 minutes
after the setting change, therefore, you must allow this time to pass before verifying the effect.
6-28
Activating outputs without
authentication
It is possible to programme a certain number of outputs that can be viewed and
activated at the keypad without authentication (i.e. without entering a user code).
Access to these outputs depends on the type of keypad in use:
•
for keypads with keys, you must activate the “Output control” shortcut (shortcut n.
21:
) associated with one of the
, ...,
•
for Alien keypads, you must access the “Commands” section by pressing the
button, then the “Domotics” section.
The outputs that can be activated from a keypad with the “NNN” address will be those
associated with a specific user code. The keypad, code and relative outputs must be
programmed in accordance with the following procedure:
Via Keypad
1. Access the section of the Installer menu for the programming of the “NNN” key-
pad you wish to associate with the outputs :
Type-in Code
(Installer)
, PROGRAMMING Keypads
.
Select peripheral
,
Keypad “NNN”
2. Access the “F1/4KeyShortcuts” section and select a function key
3. Access the “Type” section and associate the selected function key with the “Out-
put control” shortcut.
4. DO NOT ENABLE the “Requires code” option for the shortcut associated with the
function key undergoing programming.
5. Go back to the installer menu and access the “Codes” section.
6. Select the user code shown in the table in accordance with the control panel
model undergoing programming:
Keypad number
User code number
505 / 515
1050 / 1050L
10100L
001
026
041
086
002
027
042
087
003
028
043
088
004
029
044
089
005
030
045
090
006
/
046
091
007
/
047
092
008
/
048
093
009
/
049
094
010
/
050
095
011
/
096
012
/
097
013
/
098
014
/
099
015
/
100
Type
ZoneBypass menu
Voice memo
Output control
KEYP. NNN
Type
Options
KEYP. NNN
Options
F1/4KeyShortcuts
SHORTCUT F. KEYS
F1
F2
F3