Installation and programming manual
Options and programming methods
87
Following are the events which can be enabled/disabled by means of keys
and
:
•
Zone fuse fault
•
IBUS fuse fault
•
Low battery
•
Mains failure
•
Tel. line down
•
Jamming
•
Low battery WLS
•
WLS zone loss
•
Nexus fault
•
Detector dusty
•
Zone faults
•
Sounder faults
•
Power faults
•
LossTamp.ongoing
The last item groups the following events:
•• Panel opened
•• Dislodged panel
•• Expansion tamper
•• Keypad tamper
•• Reader tamper
•• Sound.flash.Tamp
•• Nexus tamper
•• V-Monitor tamper
•• Expansion loss
•• Keypad loss
•• Reader loss
•• Sound.flash.Loss
•• Nexus loss
•• Scomp. V-Monitor
•
IP conn. lost
4. Press
to confirm and exit.
Serial number
Section for the visualization of the Control panel serial number.
Via PC
6-27-1
Telephone line adjustment
The “OverThePhoneVol.” and “Tel. input gain” parameters can be used to correct the
voice functions of the dialer and the DTMF tones. The values of these parameters affect
each other, therefore, and a good result is always a compromise.
If you are not using a GSM interface, you should:
•
Adjust one parameter at a time and carry out tests to verify the result.
•
Increase/decrease the values in small steps (for example, from 25 to 22 and not
from 25 to 15).
•
If the DTMF tones are not recognized, or are recognized with difficulty, decrease the value
of the “Volume Tel.voice” parameter (in small steps of 2 or 3 units) and verify the effect. If
there is no improvement, increase the value of the “VolumeTel. In.” parameter until an
acceptable level is achieved.
Periodic ev.
Time per. Event
PeriodicInterval
Options
PROGRAMMING
Default settings
User functions
Other parameters
Other parameters
Periodic Ev.
Mains fail.Delay
LocKpadMessTimes
Periodic ev.
Periodic ev. 001
Periodic ev. 002
Periodic ev. 003
Table 57:
Other parameters - via SmartLeague software programme
Option
Part of the system
Template/section
Periodic ev.
SmartLiving System
Parameters settings - periodic event
Mains fail.Delay
Parameters settings - I-BUS parameters
LocKpadMessTimes
Keypads
Parameters settings - Keypad parameters
OverThePhoneVol.
SmartLiving System
Parameters settings - Telephone options
Ring sensitivity
SmartLiving System - Telephone
Parameters settings - Telephone line parameters
Wireless superv.
SmartLiving System
Parameters settings - Control panel parameters
Tel. input gain
Parameters settings - Telephone options
LowBattery delay
Parameters settings - I-BUS parameters
LinedownDelay
SmartLiving System - Telephone
Parameters settings - Telephone dialer parameters
FaultForNotReady
SmartLiving System
Programming - Forced arming faults