84
Options and programming methods
Note
The data relating to the wireless detectors and keyfobs will not reset on the control panel, nor will
the devices simulated by the Air2-BS100 transceiver be deleted from the configuration.
3. The control panel will ask for confirmation of this command (press
).
Via PC
The SmartLeague software programme allows you to reset the control panel default
values only for the following parameters relative to the programming of events:
•
digital dialer parameters
•
“CCC” field of CONTACT-ID protocol of the zones
•
phone calls on activation and restoral
•
outputs on activation or restoral
•
message playback on keypads on activation or restoral
•
SIA protocol parameters
6-26
User functions
This section describes the functions the installer has in common with the user.
Via Keypad
1. Access the “User functions” section:
Type-in Code
(Installer)
, PROGRAMMING User functions
.
2. Use keys
and
to select the function then press
:
View
•
Events log
- allows you to view all the events
saved to the log.
•
Alarms log
- allows you to view all the events
relating to zone/partition alarm and
tamper saved to the log.
•
Faults log
- allows you to view all the fault events saved to the log.
•
Arm/Disarm ops.
- allows you to view all the arm/disarm operations saved to the
log.
Use key
or
to scroll the chronological events list. For some events, key
allows
you to view the partitions details. For example, the details of an “Arm” command will show
the code and keypad concerned and, if you press
, the list of partitions involved.
•
Nexus status
- allows you to view (on the display) the following parameters of the
Nexus device:
1° line:
GSM network provider (Vodafone, etc.), on the left side and BUS connections
on the right side of the string:
- if nothing appears, it means that the Nexus/G is connected to the BUS
- if the letter “
G
” appears, it means that the Nexus/G is connected to the BUS
and that the GPRS service is available
- if the letter “
C
” appears, it means that the Nexus/G is connected to the BUS
and that a teleservice request (TCP connection) or SIA-IP event report is being
sent
- if “
--
” appears, it means that the Nexus is connected to the BUS
2° line:
GSM signal reception (value between 1 and 100)
3° line:
balance, at the last operation (expressed in the local currency)
4° line:
faults present - access the “View-Faults” section for details.
•
System voltage
- allows you to view the voltage the system uses.
•
Zone status
- allows you to view the status of all the zones. Use keys
and
to scroll the list of accessible zones. The display shows the following zone
parameters:
Table 55:
Factory default settings - via SmartLeague software programme
Option
Part of the system
Template/section
CONTACTIDDefault
SmartLiving System - Events
Programming - Maintenance events
CONT-ID enumer.
SmartLiving System - Terminals
Programming - “Rename the CCC in sequential
mode”
DeletePrg.events
SmartLiving System - Events
Programming - Maintenance events
Installer Code
18:23 03/30/13
KEYP. 001
VIEW
Events log
Alarms log
Faults log
PROGRAMMING
Messages
Default settings
User functions
User functions
View
Outputs ON/OFF
Set date/time