Installation and programming manual
General information
7
•
FLEX5/P input/output expansion boards
•
Joy/MAX, Joy/GR, cCode/G, nCode/G keypads
•
nBy/S outdoor-mount proximity readers
•
nBy/X universal-mount proximity readers
•
IB100/RP BUS isolator
•
Self-powered IB100/A BUS isolator
•
nCard access-control card for proximity readers
•
Tag for nKey or nBoss proximity readers
•
Self-powered sounderflashers for outdoor installation: Ivy, Ivy-F, Ivy-M, Ivy-FM, Ivy-
B, Ivy-BF, Ivy-BM, Ivy-BFM
•
Wireless devices AIR2, AIR2-BS100 (transceivers), Air2-IR100 (PIR detectors), Air2-
MC100 (magnetic contacts)
TYPE B NOTIFICATION
APPARATUS
ATS2 notification apparatus (refer to EN50131-1:2008-02, paragraph 8.6 Notification,
Table 10, page 46, Grade 2 and EN50136) characterized by:
•
Transmission time - classification D2 (60 seconds)
•
Transmission time - max. values M2 (120 seconds)
•
Classification time - classification T2 (25 hours)
•
S0 Substitution security (no detection of device substitution)
•
I0 Information security (no detection of message substitution)
ATS4 notification apparatus (refer to EN50131-1:2008-02, paragraph 8.6 Notification,
Table 10, page 46, Grade 3 and EN50136) features the following parameters (available
on SmartLAN/G and SmartLAN/SI only):
•
Transmission time - classification D2 (60 seconds)
•
Transmission time - max. values M2 (120 seconds)
•
Classification time - classification T3 (300 minutes)
•
S1 Substitution security (measures aimed at detecting the substitution of the
transceiver of the supervised site by means of an identifier code or address in all
messages sent over the transmission link).
•
I2 Information security (measures aimed at impeding unauthorized changes to
transmitted information).
1-4
Patents Pending
The SmartLiving series of control panels employs the following patented technologies.
•
Input/Output Terminals
: each terminal on-board the control panel, keypads and
expansion boards can be configured as either an input or output zone.
•
nBy/X proximity reader
: this reader has been especially designed to flush-mount
to all models of electrical light-switch backboxes.
•
Learn zone balancing
: this option allows the control panel to save the balancing
values of all the system zones automatically, thus eliminating the task of typing
them in.
1-5
Manuals
1-5-1
Installation and
programming manual
(this manual)
This manual (not included in the package) can be purchased from your retailer. You (the
installer) should read carefully through it in order to become familiar with all the
components and operating procedures of the SmartLiving system.
In order to provide adequate protection, the installer must adhere to all the
manufacturer's guidelines relating to the active and passive security devices of this
system.
1-5-2
Installation and
programming guide
This guide is included in the control panel package and provides all the instructions and
illustrations necessary for fast installation and programming of the SmartLiving system.
It provides step by step descriptions of the procedures required for the system wiring,