24
Installation
3-1-3
Maximum current - normative
references
Compliance with EN50131, CEI 79 or CEB T014 requires full observation of the rules
(relating to the applicable normative and the model of the control panel concerned)
presented in the Table below.
The system must be arranged in such a way that the current draw under normal
circumstances does not exceed the maximum current allowed and the power source for
the battery charge is always available.
3-1-4
Connecting the backup battery
The backup battery [A] connection must be completed during the phase described in
Chapter 4 - First power up
.
The SmartLiving 505, 515 and 1050 control panels house one lead battery @12V 7Ah.
The SmartLiving 10100L house two lead batteries, one @12V 17Ah (Max) and the other
@12V 1.2Ah.
Note
The battery casing must have HB flame rating or higher.
Using the battery wire [B] (included), connect the battery directly to the control panel
motherboard.
ATTENTION!
Ensure that battery polarity is correct:
- black wire = negative
- red wire = positive
The backup battery is the secondary power source which powers the system during
mains failure (230Vac, 50Hz).
Once powered up, the panel will charge and monitor the battery automatically. The
panel tests the efficiency of the battery by simulating load current demand at regular 4
minute intervals. If the control panel detects a voltage inferior to 10.4V (battery
inefficient), it will generate a Low battery event that will not clear until the voltage goes
back to over 11.4V.
This fault will be signalled on the yellow LED on the keypads. To view the fault event,
work through the following steps:
Access User menu
, then View
, Faults Ongoing
.
N
L
230V ~ 50/60 Hz
AC
Input
N L
230V ~ 50/60 Hz
AC Input
SmartLiving10100L
SmartLiving 1050
Table 33:
Maximum current permitted
Norm
SmartLiving intrusion control panels
505
515
1050
10100L
EN50131-3
Maximum current
permitted
1.2A
1.2A
2.6A
3.5A
Current reserved for
the battery charge
1A
1A
2A
2A
CEI 79-2
Maximum current per-
mitted
1.2A
1.2A
2.6A
3.5A
Current reserved for
the battery charge
1A
1A
2A
2A
CEB T014
Maximum current per-
mitted
1.2A
1.2A
2.3A
2.7A
Current reserved for
the battery charge
1A
1A
2A
2A
Faults
Low battery