Installation and programming manual
Options and programming methods
57
“Delayed” and “Delayed unhidden” zones are delayed during entry and exit phases, in
accordance with the respective “Entry Time” and “Exit Time” settings (refer to
paragraph 6-13 Partitions
). A “Delayed unhidden” zone behave as follows:
•• if violated when the system is disarmed, it will switch Off the blue LED on the
keypad
•• if the “View open zones” option is enabled, it will be shown on the keypad
•• it will not generate “Partition not ready” events
•• On arming from a keypad, the zone will appear as a violated zone but, when the
arming operation is confirmed, will behave as a delayed zone and will not
generate an alarm.
•• if the “OpenZonesArmLock” option is enabled and the zone is violated, it will
appear as a violated zone but, when the arming operation is confirmed, will
behave as a delayed zone and will not generate an alarm.
•• if the “OpenZonesArmLock” option is enabled, the zone is violated and instant
arming is required, the zone will appear as a violated zone and when the partition
arming operation is confirmed, the partitions the zone belongs to will not be
armed.
Options
The available options (refer to
Appendix A, Technical terminology and Glossary
) must
be enabled/disabled by keys
and
:
•
Interior
•
Auto-bypassable
•
Unbypassable
•
Chime
•
Test
•
TampReed/FollPir
•
Broadcast RF
•
Use sensor LED
The last three options apply to “Wireless” zones only, a full description of which follows.
•
No-Unbypassable
If this option is enabled, the zone will operate as an “Auto-
bypassable” zone, with the difference that it will be automatically unbypassed when
the partition next disarms.
•
NoArmIfNotReady
. If this option is enabled, the zone, even if it is a 24H,
automation or delayed zone, will not arm when it is not in standby status. This
option, for 24H or automation zones, can be used for the management of the “anti-
mask” function of detectors which have this feature.
Partitions which at the moment of arming have open zones with this option enabled,
will not be armed; instead, the system will generate a failed arming even (“Failed to
arm”).
•
Delay time 2
. If this option is enabled, delayed zones will activate the second
partition entry time. If this option is not enabled, delayed zones will activate the first
partition entry time.
•
Last exit zone
. If this option is enabled, and the zone passes from standby status
to alarm status while the partition exit time is running, the exit time will be forced to
15 seconds. If the zone passes from alarm status to standby status, the exit time
will be forced to 5 seconds.
Option
If enabled
If disabled
TampReed/FollPir
•
Air2-IR100
- in order to increase battery life, the infrared
sensor will deactivate when the partitions it belongs to are
disarmed and will only activate when the partitions it
belongs to arm.
Deactivated detectors do not generate alarms. There may
be up to a 3 minute delay between the partition arming
command and when the detector actually arms.
•
Air2-MC100/MC200
- detects magnetic-contact tamper
when both reeds are in standby status.
•
Air2-IR100
- the PIR detector will be active at all
times.
•
Air2-MC100/MC200
- tamper on the magnetic
contact will not be detected.
Broadcast RF
This option must be enabled when the zone and one of the ter-
minals of the Air2-MC100 device (“T1” or “T2”) is configured as
an “output”. Assures the activation/deactivation of the output
within 2 seconds of the control panel command.
The activation/deactivation of the “wireless” output
occurs within 2 minutes of the command from the con-
trol panel.
Use sensor LED
The red LED of Air2-IR100 and Air2-MC100/MC200 devices sig-
nals alarm and tamper conditions on the device.
Note
This option will be enabled on all the terminals of the Air2-
MC100.
The red LED of Air2-IR100 and Air2-MC100/MC200 will
be “Off” at all times.