56
Commissioning
Chapter 3 - Commissioning
3.1
Configuring Basic Parameters of Base
Station
After completing the installation process, as described in the preceding chapter,
some basic parameters must be configured using the Monitor application via the
MON port of the NPU. These parameters are necessary to enable remote
management using SNMP or Telnet.
The basic parameters are listed in
Table 3-1
. Refer to
Chapter 4
for detailed
information on the applicable parameters.
The following are the guidelines for configuring the basic parameters:
Table 3-1: Basic NPU Parameters
Management Option
Parameters
MGMT port
¢
Management Port IP address
¢
Management Port Subnet Mask
¢
Management Port Gateway
¢
Management Port Destination Subnet
¢
Management Port Destination Subnet Mask
¢
Management Port Management Traffic Enable/Disable
DATA port
¢
Data Port IP address
¢
Data Port Subnet Mask
¢
Data Port Gateway
¢
Data Port Management VLAN ID
¢
Data Port Management Traffic Enable/Disable
¢
Data Port Speed
Authorized Managers
(per manager)
¢
IP Address
¢
Send Traps
¢
Read Community
¢
Write Community