NPU Parameters Summary
WiLink-I Modular Base Station System Manual
183
Uplink Rate
Applicable only if Multirate in AU is
disabled:
1 - BPSK 1/2
2 - BPSK 3/4
3 - QPSK 1/2
4 - QPSK 3/4
5 - QAM16 1/2
6 - QAM16 3/4
7 - QAM64 2/3
8 - QAM64 3/4
New SU: Uplink
Basic Rate.
Connected SU:
Last used rate.
Yes
SU Ethernet Port Parameters
Ethernet Port Configuration
1 - 10 Mbps Half Duplex
2 - 10 Mbps Full duplex
3 - 100 Mbps Half Duplex
4 - 100 Mbps Full Duplex
5 - Auto Negotiation
Auto Negotiation
No
SU Password
Password
Up to 20 printable characters, case
sensitive
installer
Yes
SU Bridging Parameters
Enable/Disable Limit on
Number of Supported Devices
1 - Disable
2 - Enable
Disable
Yes
Maximum Number of Supported
Devices
1 - 512
512
Yes
Bridge Aging Time
1 - 1440 minutes
3 minutes
Yes
Services - General Parameters
Service Mode
1 - Advanced
2 - Quick
Quick
Yes
Default L2/Voice Service Profile
Name of an existing L2 or Voice Service
Profile, or None.
Internet Access
L2
Yes
Table 4-22: NPU Monitor Parameters Summary
Parameter
Range
Default
Run-Time
Updated