58
Commissioning
Chapter 3 - Commissioning
3.2
Operation Verification
The following sections describe how to verify the correct functioning of the
Outdoor Units, Indoor Units, Ethernet connection and data connectivity.
3.2.1
AU-ODU LEDs
To verify the correct operation of the AU-ODU, examine the LED indicators located
on the bottom panel of the outdoor unit.
The following tables list the provided LEDs and their associated indications.
NOTE
Verifying the correct operation of the Outdoor Unit using the LEDs, as described below, is only
possible after the configuration of basic parameters has been completed.
Table 3-2: AU-ODU LEDs
Name
Description
Functionality
PWR
Power indication
¢
Off - ODU is not powered
¢
Green - ODU power is OK
ALARM
Not Used
(Red - blinks shortly during ODU power up)
ETH (WLNK)
Wireless link status indication
¢
Off - No SU is associated
¢
Green - At least one SU is associated