CHAPTER 11 A/D CONVERTER
User’s Manual U12688EJ4V0UM00
338
Figure 11-13. Example of 1-Trigger Mode (Timer Trigger Scan 1-Trigger) Operation
(a) Setting when scanning ANI0 to ANI3
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
ADCR0
ADCR1
ADCR2
ADCR3
ADCR4
ADCR5
ADCR6
ADCR7
A/D converter
INTCC110
(1)
CE bit of ADM0 is set to 1 (enable)
(8)
CC110 compare generation
(2)
CC110 compare generation
(9)
ANI2 A/D conversion
(3)
ANI0 A/D conversion
(10) Conversion result is stored in ADCR2
(4)
Conversion result is stored in ADCR0
(11) CC110 compare generation
(5)
CC110 compare generation
(12) ANI3 A/D conversion
(6)
ANI1 A/D conversion
(13) Conversion result is stored in ADCR3
(7)
Conversion result is stored in ADCR1
(14) INTAD interrupt generation
Caution The analog input enclosed in the broken lines cannot be used with INTCC11n as the trigger (n
= 0 to 3). When a setting is made to scan ANI0 to ANI7, ANI4 to ANI7 are converted in A/D
trigger mode (see (b)).
(b) Setting when scanning ANI0 to ANI7
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
ADCR0
ADCR1
ADCR2
ADCR3
ADCR4
ADCR5
ADCR6
ADCR7
A/D converter
INTCC110
(1) to (13) Same as (a)
(18) ANI6 A/D conversion
(14) ANI4 A/D conversion
(19) Conversion result is stored in ADCR6
(15) Conversion result is stored in ADCR4
(20) ANI7 A/D conversion
(16) ANI5 A/D conversion
(21) Conversion result is stored in ADCR7
(17) Conversion result is stored in ADCR5
(22) INTAD interrupt generation
Summary of Contents for V850E/MS1 UPD703100
Page 2: ...User s Manual U12688EJ4V0UM00 2 MEMO ...
Page 6: ...User s Manual U12688EJ4V0UM00 6 MEMO ...
Page 8: ...User s Manual U12688EJ4V0UM00 8 MEMO ...
Page 12: ...User s Manual U12688EJ4V0UM00 12 MEMO ...
Page 26: ...User s Manual U12688EJ4V0UM00 26 MEMO ...
Page 68: ...User s Manual U12688EJ4V0UM00 68 MEMO ...
Page 124: ...User s Manual U12688EJ4V0UM00 124 MEMO ...
Page 198: ...User s Manual U12688EJ4V0UM00 198 MEMO ...
Page 230: ...User s Manual U12688EJ4V0UM00 230 MEMO ...