CHAPTER 9 TIMER/COUNTER FUNCTION (REAL-TIME PULSE UNIT)
User’s Manual U12688EJ4V0UM00
267
The capture trigger’s active edge is set by the external interrupt mode register (INTM1 to INTM6). If both the rising
and falling edges are made capture triggers, the input pulse width from an external source can be measured. Also, if
the edge from one side is used as the capture trigger, the input pulse’s period can be measured.
Figure 9-5. Example of Capture Operation
TM11
0
CE11
INTP110
CC110
n
n
(Capture trigger)
(Capture trigger)
Remark
When the CE11 bit = 0, no capture operation is performed even if INTP110 is input.