C-8 System Board, Connectors, and Error Messages
Error Messages
When your computer’s power is switched on, the system
automatically goes through initialization, which includes
running the Power-On Self Test (POST). Fatal errors are
those that prevent the system from continuing the boot
process. If any are detected, an error message will appear on
the screen. The following list of error messages includes
causes and possible solutions.
Message
Diskette drive A Error.
Cause
Drive A is present but fails the BIOS POST diskette
tests.
Solution
Make sure the drive is defined with the correct
diskette type in the Setup Utility program and is
properly attached.
Message
Extended RAM failed at offset: nnnn.
Cause
Extended memory not working or not configured
properly at offset: nnnn.
Message
Fixed Disk 0 or Fixed Disk 1 Failure, or Fixed Disk
Controller Failure.
Cause
Fixed (hard) drive is not working or not configured
properly.
Solution
Make sure the drive is correctly identified in the
Setup utility program and is properly attached.
Message
Failing Bits: nnnn.
Cause
The hex number nnnn is a map of the bits at the
RAM address that failed the memory test. Each 1
(one) in the memory map indicates a failed bit. The
failed memory could be in System, Extended or
Shadowed memory.
Summary of Contents for PowerMate SPB-Wash
Page 55: ...4 Configuring the System System BIOS and the Setup Utility BIOS Flash Utility Video Drivers...
Page 161: ...B System Specifications Standard Features Environmental Specifications...
Page 177: ...C System Board Connectors and Error Messages System Board Connectors Error Messages Beep Codes...