CHAPTER 3
ND-45669 (E)
Page 232
Revision 2.0
CM60
COMMAND CODE
TITLE:
ATT GROUP, FUNCTIONS
60
MAT
4.
DATA TABLE:
1.
FUNCTION:
This command is used to assign a number to an ATTCON for access on a tenant basis, and define the
consoles’ night switching ability, off-hook ringing, tone ringer, password code for Attendant Lockout
and Attendant Programming.
2.
PRECAUTION:
(1)
CM60 YY = 00, 01, 02, 04, 06 require a system reset after data setting.
(2)
The password for ATTCON (YY = 30) cannot be assigned by the MAT mode menu.
(3)
When assigning a password code for an ATTCON by CM60 YY = 30, the Function Number (0/1)
is required as the first data. The purpose of Function Numbers is shown below.
0: To assign a password for ATTCON Lockout
1: To assign a password for Attendant Programming
(DISA, System Speed Dialing, Date and Time, and Tone Ringer)
(4)
This command is included in MAT mode menu “C2” (ATT Group, Functions [COM02]).
3.
ASSIGNMENT PROCEDURE:
:
Initial Data
YY
GROUP NUMBER
RELATED
COMMAND
No.
MEANING
DATA
MEANING
00
(
Group
No.
)
ATT GROUP
0
1
2
3
ATT GROUP 0
ATT GROUP 1
ATT GROUP 2
ATT GROUP 3
CM62
CM51 YY = 13
01
(
Master
)
Designation of Master ATT
within ATT Group
0
1
Master ATT
Not Master ATT
Note:
Master ATT must be
assigned to a single
ATTCON within
ATT Group.
ST
DE
+ 60YY
+
+
+
DE
(1 - 8 digits)
DATA
+
+ EXE
ATTCON
NUMBER
(0 - 7)
FUNCTION
NUMBER
(0/1)
INITIAL
INITIAL
[CM60]
ATT Group, Functions
Summary of Contents for NEAX 2000 IVS
Page 1: ...ND 45669 E ISSUE 2 PART OF STOCK 151901 Command Manual DECEMBER 1997 NECAmerica Inc ...
Page 17: ...CHAPTER 1 ND 45669 E Page 2 Revision 2 0 This page is for your notes ...
Page 77: ...CHAPTER 2 ND 45669 E Page 60 Revision 2 0 This page is for your notes ...
Page 473: ...CHAPTER 4 ND 45669 E Page 430 Revision 2 0 This page is for your notes ...